AP(config)# lldp transmit interval 30
AP(config)#
lldp transmit re-init-
delay
This command configures the delay before attempting to re-initialize after
LLDP ports are disabled or the link goes down.
SYNTAX
lldp transmit re-init-delay <seconds>
seconds - Time in seconds. (Range: 2 - 10)
DEFAULT SETTING
2 seconds
COMMAND MODE
Global Configuration
COMMAND USAGE
â—† This command configures the delay before attempting to re-initialize
after LLDP ports are disabled or the link goes down.
â—† When LLDP is re-initialized on a port, all information in the remote
systems LLDP MIB associated with this port is deleted.
EXAMPLE
AP(config)#lldp transmit re-init-delay 10
AP(config)#
lldp transmit delay-
to-local-change
This command configures a delay between the successive transmission of
LLDP advertisements initiated by a change in local LLDP MIB variables.
SYNTAX
lldp transmit delay-to-local-change <seconds>
seconds - Time in seconds. (Range: 1-8192 seconds)
DEFAULT SETTING
2 seconds
COMMAND MODE
Global Configuration
COMMAND USAGE
â—† The transmit delay is used to prevent a series of successive LLDP
transmissions during a short period of rapid changes in local LLDP MIB