EasyManua.ls Logo

Edge-Core ECS4120 Series

Edge-Core ECS4120 Series
938 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5
| SNMP Commands
SNMPv3 Commands
– 191 –
need to configure the remote agent’s SNMP engine ID before you can send
proxy requests or informs to it.
Example
Console(config)#snmp-server user steve r&d v3 auth md5 greenpeace priv des56
einstien
Console(config)#snmp-server engine-id remote 192.168.1.19 9876543210
Console(config)#snmp-server user mark r&d remote 192.168.1.19 v3 auth md5
greenpeace priv des56 einstien
Console(config)#
snmp-server view This command adds an SNMP view which controls user access to the MIB. Use the
no form to remove an SNMP view.
Syntax
snmp-server view view-name oid-tree {included | excluded}
no snmp-server view view-name
view-name - Name of an SNMP view. (Range: 1-32 characters)
oid-tree - Object identifier of a branch within the MIB tree. Wild cards can be
used to mask a specific portion of the OID string. (Refer to the examples.)
included - Defines an included view.
excluded - Defines an excluded view.
Default Setting
defaultview (includes access to the entire MIB tree)
Command Mode
Global Configuration
Command Usage
Views are used in the snmp-server group command to restrict user access to
specified portions of the MIB tree.
The predefined view “defaultview” includes access to the entire MIB tree.
Examples
This view includes MIB-2.
Console(config)#snmp-server view mib-2 1.3.6.1.2.1 included
Console(config)#
This view includes the MIB-2 interfaces table, ifDescr. The wild card is used to select
all the index values in this table.

Table of Contents

Other manuals for Edge-Core ECS4120 Series

Related product manuals