Cross Check Operations
ethernet cfm mep
crosscheck start-delay
This command sets the maximum delay that a device waits for remote MEPs to
come up before starting the cross-check operation. Use the no form to restore the
default setting.
Syntax
ethernet cfm mep crosscheck start-delay delay
delay – The time a device waits for remote MEPs to come up before the
cross-check is started. (Range: 1-65535 seconds)
Default Setting
30 seconds
Command Mode
Global Configuration
Command Usage
This command sets the delay that a device waits for a remote MEP to come up,
and it starts cross-checking the list of statically configure remote MEPs in the
local maintenance domain against the MEPs learned through CCMs.
The cross-check start delay should be configured to a value greater than or
equal to the continuity check message interval to avoid generating
unnecessary traps.
Example
This example sets the maximum delay before starting the cross-check process.
Console(config)#ethernet cfm mep crosscheck start-delay 60
Console(config)#
snmp-server enable
traps ethernet cfm
crosscheck
This command enables SNMP traps for CFM continuity check events, in relation to
the cross-check operations between statically configured MEPs and those learned
via continuity check messages (CCMs). Use the no form to restore disable these
traps.
Syntax
[no] snmp-server enable traps ethernet cfm crosscheck [ma-up |
mep-missing | mep-unknown]
ma-upSends a trap when all remote MEPs in an MA come up.
mep-missingSends a trap if the cross-check timer expires and no CCMs
have been received from a remote MEP configured in the static list.
mep-unknownSends a trap if an unconfigured MEP comes up.