EasyManua.ls Logo

Edwards STP-iXA4507 Series - 5.4.16 Readoptionfunc

Edwards STP-iXA4507 Series
163 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
STP-iXA4507 series Turbomolecular Pump
MT-91E-001-0
Page 102
SERIAL COMMUNICATION PROTOCOL
PAG
E
102
5
5.4.16 ReadOptionFunc
Function: Reading the setting value of the input operation port, TMS option, warning function, serial
communication time out, and PROG OUT/PROG IN.
Transmission frame:
*1
PCSIM
Stx
0
0
1
?
=
Etx
LRC
SIMPC
Ack
PCSIM
*1
Ack
SIMPC
Stx
0
0
1
Sp
=
Parameter 1 to 15
Etx
LRC
*1 The HEX code of ASCII character ' = ' is "3D".
Parameter
Item
Data format
Remarks
1
Input operation port setting
8-bits hexadecimal
coded ASCII
2
*1
TMS Option
Enable/Disable setting
8-bits hexadecimal
coded ASCII
3
[System reservation]
48-bits hexadecimal
coded ASCII
4
Second Damage Limit Option
Enable/Disable setting
8-bits hexadecimal
coded ASCII
5
First Damage Limit Warning
Enable/Disable setting
8-bits hexadecimal
coded ASCII
6
Pump Runtime Over Warning
Enable/Disable setting
8-bits hexadecimal
coded ASCII
7
Pump Runtime Over Warning
Hours setting (×100 hours)
32-bits hexadecimal
coded ASCII
8
Imbalance Warning
Enable/Disable setting
8-bits hexadecimal
coded ASCII
9
Pump Overload Warning
Enable/Disable setting
8-bits hexadecimal
coded ASCII
10
Pump Overload Warning
Motor current setting
16-bits hexadecimal
coded ASCII
0.1 % step
11
Pump Overload Warning
Rotational speed setting
16-bits hexadecimal
coded ASCII
0.1 % step
*1 Valid only with TMS specification

Table of Contents