Summit External Power Supplies (EPS)
Extreme Networks Consolidated ExtremeXOS Hardware Installation Guide
334
Figure 237: Installing the Redundant Power Cord
6 Connect the other end of the AC power cord into the electrical outlet (see Figure 237).
Be sure that the electrical outlet is properly grounded.
NOTE
Consider all of the equipment that is connected to the power supply circuit to ensure that the circuit is not
overloaded. Use proper overcurrent protection, such as a circuit breaker, to prevent overcurrent conditions.
The switch and each redundant power supply source in the power supply chassis should be plugged into separate
branch circuits to provide redundancy.
7 Repeat steps 1 through 6 for each EPS-600LS unit (maximum three units per EPS-C).
Removing an EPS-600LS
To remove an EPS-600LS unit:
1 Disconnect the AC power by removing the plug from the wall.
2 Release the cable clip securing the AC power cord to the EPS-600LS unit.
3 Disconnect the AC power cord from the EPS-600LS unit.
4 Loosen the captive screws on the EPS-600LS unit securing it to the EPS-C.
5 Slide the EPS-600LS unit out of the EPS-C.
! See Manual
O.T.P
DC OK
AC OK
EPS-C_06A
To A C
Power Cord
Cable Clip