Configuring Basic Software Features
December 2005 © Foundry Networks, Inc. 3 - 5
Syntax: [no] snmp-server enable traps holddown-time <secs>
The <secs> parameter specifies the number of seconds and can be from 1 – 600 (ten minutes). The default is 60
seconds.
Disabling SNMP Traps
Foundry devices come with SNMP trap generation enabled by default for all traps. You can selectively disable one
or more of the following traps.
NOTE: By default, all SNMP traps are enabled at system startup.
Layer 2 Traps
The following traps are generated on devices running Layer 2 software:
SNMP authentication keys
Power supply failure
Fan failure
Cold start
•Link up
Link down
Bridge new root
Bridge topology change
Locked address violation
Layer 3 Traps
The following traps are generated on devices running Layer 3 software:
SNMP authentication key
Power supply failure
Fan failure
Cold start
•Link up
Link down
Bridge new root
Bridge topology change
Locked address violation
•BGP4
OSPF
VRRP
VRRPE
To stop link down occurrences from being reported, enter the following:
FESX424 Router(config)# no snmp-server enable traps link-down
Syntax: [no] snmp-server enable traps <trap-type>
NOTE: For a list of the trap values, see the Foundry Switch and Router Command Line Interface Reference.