EasyManuals Logo

Foundry Networks FESX User Manual

Foundry Networks FESX
820 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #738 background imageLoading...
Page #738 background image
Foundry Configuration Guide for the FESX, FSX, and FWSX
A - 12 © Foundry Networks, Inc. December 2005
Alert Management module at slot <slot-num>
state changed from <module-state> to
<module-state>.
Indicates a state change in a management
module.
The <slot-num> indicates the chassis slot
containing the module.
The <module-state> can be one of the
following:
• active
•standby
•crashed
• coming-up
• unknown
Alert OSPF LSA Overflow, LSA Type =
<lsa-type>
Indicates an LSA database overflow.
The <lsa-type> parameter indicates the type
of LSA that experienced the overflow
condition. The LSA type is one of the
following:
• 1 – Router
• 2 – Network
•3 – Summary
•4 – Summary
• 5 – External
Alert OSPF Memory Overflow OSPF has run out of memory.
Alert Power supply <num>, <location>, failed A power supply has failed.
The <num> is the power supply number.
The <location> describes where the failed
power supply is in the chassis.
Alert Temperature <degrees> C degrees, warning
level <warn-degrees> C degrees, shutdown
level <shutdown-degrees> C degrees
Indicates an overtemperature condition on
the active module.
The <degrees> value indicates the
temperature of the module.
The <warn-degrees> value is the warning
threshold temperature configured for the
module.
The <shutdown-degrees> value is the
shutdown temperature configured for the
module.
Table A.3: Foundry Syslog Messages (Continued)
Message Level Message Explanation