9.2.11 UDLD
9.2.11.1 UDLD Config
Figure : UDLD Config
Selection Criteria
Global Port Mode - Specifies the UDLD Global Port mode. It has three options : Disable, Normal
and Aggressive.
Interface - Specifies the list of all the physical ports on which UDLD can be configured.
Port Mode - Specifies the UDLD Port mode for the selected interface. It has three options : Disable,
Normal and Aggressive.
Configurable Data
Message - Specifies the Message Interval in seconds to send of messages in steday state. The
range is from (7 to 90). Default value is 15 seconds.
Command Buttons
Apply - Send the updated screen to the switch and cause the changes to take effect on the switch
but these changes will not be retained across a power cycle unless a save is performed.