10.4.12 Error Disable Recovery
10.4.12.1 show errdisable recovery
This command displays the reason of error disable, timer status and error disable information of port
status.
Syntax
show errdisable recovery
Default Setting
None
Command Mode
Privileged Exec
Display Message
ErrDisable Reason: The cause reason for error disable occurring.
Timer Status: Admin mode of error disable reason.
Timer Interval: The error disable recovery interval.
Interface: Port number of error disable occurring port.
ErrDisable Reason: The cause reason for error disable occurring.
Time Left (Sec): The lefting recovery time of error disable port.
10.4.12.2 errdisable recovery cause
The command set admin mode for error disable cause.
Syntax
errdisable recovery cause storm-control
no errdisable recovery cause storm-control
no - This command set the admin mode of error disable cause by storm control to default.
Default Setting
Disable
Command Mode
Global Config