10.6.5.16 snmp-server engineID
This command create a snmp engineID.
Syntax
snmp-server engineID remote <ipAddr | ipv6Addr> <engineid-string>
no snmp-server engineID remote <ipAddr | ipv6Addr> <engineid-string>
<ipAddr | ipv6Addr> - IPv4 or IPv6 address of SNMP host which will receive SNMP trap/inform
from this switch.
<engineid-string> - Engin ID for the selected host. The Engined ID are up to 24 hexadecimal
characters in length
no - This command delete a snmp engineID.
Command Mode
Global Config