10.6.18.7 sflow poller
A data source configured to collect counter samples is called a poller. Use this command to enable a new
sFlow poller instance for this data source if <rcvr_idx> is valid.
Syntax
sflow poller {<rcvr-indx> | interval <poll-interval>}
no sflow poller [ interval <poll-interval>]
<rcvr_idx> - Enter the sFlow Receiver associated with the sampler/poller. A value of zero (0) means
that no receiver is configured. The range is 1-8. The default is 0.
<poll-interval> - Enter the sFlow instance polling interval. A poll interval of zero (0) disables counter
sampling. When set to zero (0), all the poller parameters are set to their corresponding default value.
The range is 0- 86400. The default is 0. A value of N means once in N seconds a counter sample is
generated.
no - Use this command to reset the sFlow poller instance to the default settings.
Default Setting
None
Command Mode
Interface Config