A - Identification
Status Description
blue on
The server has been highlighted using the iRMC S6
web interface or the ID button on the front panel for
easy identification.
flashing blue
The server has been highlighted for easy
identification using the iRMC S6 (A
VR) with disabled
local VGA output.
B - CSS (Customer Self Service)
Status Description
off No critical event detected (CSS component).
orange on Prefailure event detected (CSS component).
flashing orange CSS component failure detected.
C - GEL (Global Error LED)
Status Description
off No critical event detected (non-CSS component).
orange on Prefailure event detected (non-CSS component).
flashing orange
Non-CSS component failure detected.
Possible causes:
System is out of the specified temperature range
Defective sensor
CPU error
Error detected by server management software