A - Identification
Status Description
blue on
The server has been highlighted using the iRMC S6
web interface or the ID button on the front panel for
easy identification.
flashing blue
The server has been highlighted for easy
identification using the iRMC S6 (A
VR) with disabled
local VGA output.
B - CSS (Customer Self Service)
Status Description
off No critical event detected (CSS component).
orange on Prefailure event detected (CSS component).
flashing orange CSS component failure detected.
C - GEL (Global Error LED)
Status Description
off No critical event detected (non-CSS component).
orange on Prefailure event detected (non-CSS component).
flashing orange
Non-CSS component failure detected.
Possible causes:
– System is out of the specified temperature range
–
Defective sensor
– CPU error
– Error detected by server management software
Appendix A
346 Upgrade and Maintenance Manual RX1330 M5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX1330 M5 and is the answer not in the manual?

Fujitsu PRIMERGY RX1330 M5 Specifications

General IconGeneral
Processor Sockets1
MemoryUp to 128 GB
Memory TypeDDR4
Form Factor1U rack server
Memory Slots4 DIMM slots
StorageUp to 4x 3.5" or 8x 2.5" drives
RAID SupportRAID 0, 1, 5, 6, 10, 50, 60
Network2x 1GbE LAN ports
Power Supply800W