Page #350 background imageLoading...
Page #350 background image
Power-on indicator / AC connected indicator (2)
Status Description
off The server is switched off and not connected to the
mains.
green on The server is switched on.
flashing white The iRMC firmware is starting up after the server has
been connected to the mains.
white on The server is switched off and connected to the mains
(standby mode).
After connecting the server to the mains, it
will take about 60 seconds until the server
will enter standby mode and can be switched
on.
exchange flashing
green and white
The server has been switched on but Power Cycle
Delay settings delay it from turning on for a specified
time.
CSS indicator (3)
Status Description
off No critical event detected (CSS component).
orange on Prefailure event detected (CSS component).
For HDDs, see also "HDD prefailure detection" on
page 351
.
flashing orange CSS component failure detected.
Global Error indicator (4)
See also "iRMC-related status signals" on page 351.
Status Description
of
f No critical event detected (non-CSS component).
orange on Prefailure event detected (non-CSS component).
Appendix A
350 Upgrade and Maintenance Manual RX1330 M5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX1330 M5 and is the answer not in the manual?

Fujitsu PRIMERGY RX1330 M5 Specifications

General IconGeneral
Processor Sockets1
MemoryUp to 128 GB
Memory TypeDDR4
Form Factor1U rack server
Memory Slots4 DIMM slots
StorageUp to 4x 3.5" or 8x 2.5" drives
RAID SupportRAID 0, 1, 5, 6, 10, 50, 60
Network2x 1GbE LAN ports
Power Supply800W