4.10.3 Set Date and Time and Serial Number
To verify the date and time set in the system controller and make sure that they are correct:
1. Use the
and keys to select the year, month, day, hour, minute, or second you wish to
modify, then use the
and keys to set the correct value for the selected item. Press Ent:
[Main Menu > SETUP > (password) > Time]
Set real time
Year Month Day Hour Min Sec
2011 09 30 23 58 00
Figure 48: Date and time
2. Enter the serial number of the Power+ system in the system controller, and then press Ent:
[Main Menu > SETUP > (password) > Site]
Site number: 013271
Figure 49: Site number
Note: The serial number of Power+ is on a bar-code label at the bottom of the unit, on the left hand side.
4.10.4 Define the IP Address of the Power+
This procedure assigns the Power+ an address within the domain of the customer's computer network.
1. Obtain IP, gateway, and mask addresses from the system administrator of the organization for the
Power+ system.
2. Select Set IP ADDRESS in the Network menu:
[Main Menu > SETUP > (password) > Ent > Service > SC2012 > Network]
1> Set IP ADDRESS 157.211.000.253
2> Set GATEWAY 157.211.000.251
3> Set MASK 255.255.255.000
4> Store 5> SNMP factor Select:1
Figure 50: Network menu