5-32
Supplement
Position of the registration mark is measured
at the center of the line.
9 Using the scanned registration mark for adjusting, measure
the distance of how much the comparison registration mark
needs to be moved so both will overlap, and record the
value. As an example, in the gure above, it needs to move in
negative directions for both X and Y directions, so both of the
adjustment values will be a negative values.
10 Press the [3] key (X).
SENSOR OFFSET ADJ. X screen is displayed.
Supplement
Setting range is from -3.0mm to +3.0mm.
11 Press the POSITION ( ) key and increase or decrease the
setting value. Set the X value measured in step 9.
12 Conrm the setting and press the POSITION ( ) key
(PREVIOUS).
SENSOR OFFSET ADJ. is selected and it will return to SENSOR
OFFSET ADJ. screen.
13 Press the [4] key (Y).
SENSOR OFFSET ADJ. Y screen is displayed.
Supplement
Setting range is from -3.0mm to +3.0mm.
14 Press the POSITION ( ) key and increase or decrease the
setting value. Set the Y value measured in step 9.
15 Conrm the setting and press the POSITION ( ) key
(PREVIOUS).
SENSOR OFFSET is selected and it will return to SENSOR OFFSET
ADJ. screen.