Troubleshooting code Failure level Recovery action
enabled in email settings for
Maintenance Utility.
To receive error notification of
NAS unified firmware
configuration backup by email,
disable SMTP authentication in
email settings for Maintenance
Utility.
1. Start Maintenance Utility.
2. Click Administration >
Alert Notifications > Email
and confirm the email
settings are valid.
Note: If the user account control in Windows started, click Continue.
SVP RMI-API Forward Server
The following example is a normal log output when the server starts and
terminates normally.
[2015/03/17 15:49:09.638][INFO ][TRRMIS002001][RMI-API Forward Server]
[Initializing]
[2015/03/17 15:49:16.544][INFO ][TRRMIS002002][RMI-API Forward Server][Ready]
[2015/03/17 18:50:59.982][INFO ][TRRMIS002012][RMI-API Forward Server][Stopping]
[2015/03/17 18:51:00.003][INFO ][TRRMIS002013][RMI-API Forward Server][Stopped]
The following example is when a log output contains errors at termination.
[2015/03/17 15:49:09.638][INFO ][TRRMIS002001][RMI-API Forward Server]
[Initializing]
[2015/03/17 15:49:10.001][ERROR][TRRMIS002005][RMI-API Forward Server][Failed :
Environment is invalid.]
[2015/03/17 15:49:10.102][INFO ][TRRMIS002004][RMI-API Forward Server][Failed]
The following table lists troubleshooting codes and recovery actions.
Troubleshooting code
Failure level Recovery action
TRRMIS002001 INFO
Output when the RMI-API
Forward Server service starts.
To confirm that the RMI-API
Forward Server service started
normally, match it to the log
Troubleshooting the storage system 351
Service Guide for VSP Gx00 and VSP Fx00 Models