[2015/12/03 09:48:25.174][INFO ][TRMAAS000007][Web Application Server][Stopped]
The following table lists the troubleshooting codes and recovery actions.
Troubleshooting code Failure level Recovery action
TRMAAS000001 INFO Output when the Web
Application Server starts. To
check whether the Web
Application Server is running
normally, check whether this
troubleshooting code and
TRMAAS000002 are output.
TRMAAS000002 INFO Output when the Web
Application Server started
completely.
TRMAAS000003 WARN The ports necessary for the
Web Application Server service
cannot be used.
Check whether the ports output
to the logs are not used in
other applications and change
the application port numbers if
possible. If they cannot be
changed, see and change the
port numbers of
MAPPWebServer.
TRMAAS000004 ERROR The ports necessary for the
Web Application Server service
cannot be used.
Check whether the ports output
to the logs are not used in
other applications and change
the application port numbers if
possible. If they cannot be
changed, see and change the
port numbers of
CommonJettyStart.
TRMAAS000005 ERROR The ports necessary for the
Web Application Server service
cannot be used.
Check whether the ports output
to the logs are not used in
other applications and change
the application port numbers if
possible. If they cannot be
changed, see and change the
port numbers of
CommonJettyStop.
TRMAAS000006 INFO Output when the Web
Application Server stops.
To check whether the Web
Application Server stopped
354 Troubleshooting the storage system