TRRMIS000002 INFO Output when the start of the
RMI-API Server service is
completed normally.
TRRMIS000003 WARN
Reading the environment
setting files necessary for the
RMI-API Server service failed.
Restart the SVP.
If the condition does not
change after restarting the SVP,
set it up again.
TRRMIS000004 WARN
Operating with the default
value indicated in the log
content because the
environment setting
information necessary for the
RMI-API Server service could
not be obtained.
Restart the SVP.
If the condition does not
change after restarting the SVP,
set it up again.
TRRMIS000005 WARN
Operating with the default
value indicated in the log
content because the acquisition
of the environment setting
information necessary for the
RMI-API Server service failed.
Restart the SVP.
If the condition does not
change after restarting the SVP,
set it up again.
TRRMIS000006 WARN
The port number used of the
RMI-API Server service is
already used.
Check that another application
is not using the port number
indicated in the log content and
close the application. Then stop
the appropriate storage system
from the Storage Device List
and restart it.
Check the port number key
using the port number indicated
by the log content and change
it to another port number (see
Changing SVP port numbers). If
no port management number
key corresponding to the port
number indicated by the log
content exists, the port number
cannot be changed.
Troubleshooting the storage system 361
Service Guide for VSP Gx00 and VSP Fx00 Models