Loading...
TRRMIS000007 ERROR
The port number used of the
RMI-API Server service is
already used.
Check that another application
is not using the port number
indicated by the log content
and close the application.
Check the port number key
using the port number indicated
by the log content and change
it to another port number (see
Changing SVP port numbers). If
no port management number
key corresponding to the port
number indicated by the log
content exists, the port number
cannot be changed.
TRRMIS000008 WARN
The file operation indicated by
the log content failed in the
RMI-API Server service.
Another application can access
the file. Close all other
applications, and then stop the
appropriate storage system
once from the Storage Device
List and restart it.
TRRMIS000009 ERROR
An unexpected error occurred
in the RMI-API Server service.
Gather dump files.
Collect the dump files (see
Using the Dump tool on
page 379).
If the collection fails, collect the
target files manually (see
Collecting dump files manually
on page 380).
TRRMIS000010 WARN
The connection to the
necessary services failed in the
RMI-API Server service.
Stop the appropriate storage
system once and restart it.
If the condition does not
change after restarting, restart
the SVP.
If the condition does not
recover after restarting the SVP,
set it up again.
TRRMIS000011 ERROR
The connection to the
necessary services failed in the
RMI-API Server service.