EasyManua.ls Logo

Honeywell equIP Series - Managing Logs

Honeywell equIP Series
148 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
62
Configuring HDXG Camera Settings
To set the Manual AE mode:
1. From the OSD main menu, press 5 to select Camera Options.
2. Press 2 to select Exposure Control.
3. Press 2 to set the Manual AE Mode to one of the following:
Iris (default): Provides manual iris control while the camera controls the
gain and shutter automatically.
Gain: Provides manual gain control while the camera controls the iris
and shutter automatically.
Full: Provides access to shutter speed, AGC level settings, and to
manual iris control.
Shutter: Provides manual shutter control while the camera controls the
iris and gain automatically.
4. If Full is selected, do the following:
a. Press ESC to return to the previous menu.
b. Press 3 to select Full Manual Settings.
c. Set the Shutter Speed to one of the following:
NTSC = 1/60 (default), 1/120, 1/180, 1/250, 1/500, 1/1000, 1/2000, 1/4000,
1/10000, 1/30000
PAL = 1/50 (default), 1/100, 1/150, 1/250, 1/500, 1/1000, 1/2000, 1/4000,
1/10000, 1/30000
d. Set the AGC Level. Choose a value from 0 (default) through 30 dB.
e. Manually control the iris using Iris Open and Iris Close on the PTZ
controls in the Live View tab (see Figure 4-3 on page 30).
To slow the AE response speed:
1. From the OSD main menu, press 5 to select Camera Options.
2. Press 2 to select Exposure Control.
1. Press 4 to select Slow AE Response.
2. Type a value from 1 (default) through 254 and then press ENTER.