EasyManua.ls Logo

Honeywell equIP Series - Configuring Tamper Detection Settings

Honeywell equIP Series
148 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EQUIP
®
Series ACUIX™ IP PTZ Dome Installation and Configuration Guide
Document 800-04194V1 Rev A 97
07/11
Configuring Tamper Detection Settings
You can set tamper detection parameters for the video signal. When any of the
parameters are exceeded, a message appears on the screen to notify you of
potential tampering.
All tamper detection settings are disabled by default. However, to avoid false
alarms, Honeywell Systems recommends that you:
Disable ALL thresholds (blur, blinding, and scene change):
When a large part of the image is covered by the privacy zone.
When the video is captured under low light conditions.
When you restart the dome.
Disable the scene change threshold:
When running any preset tour or mimic tour.
When the OSD menu is enabled or any other text is overlaid on the
video.
Setting the Blur Threshold
You can set the amount of blur that is acceptable, before a notification is
triggered alerting the operator to potential tampering.
To set the blur threshold:
1. Click the Video Analytics tab.
2. In the Tamper Detection Settings panel, in the Blur Threshold box, select
one of the following:
Disable (default)
High (80%)
Medium (50%)
•Low (30%)
3. Click Apply.