EasyManuals Logo

Honeywell equIP Series Installation And Configuration Guide

Honeywell equIP Series
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #89 background imageLoading...
Page #89 background image
EQUIP
®
Series ACUIX™ IP PTZ Dome Installation and Configuration Guide
Document 800-04194V1 Rev A 69
07/11
Line lock can also help an analog VCR to remain in sync when switching
between properly adjusted, line-locked cameras. Line lock is generally of no
benefit with digital (LCD or flat screen) monitors and DVRs.
Note You need an AC power supply to use this feature.
To enable/disable vertical phase edge:
1. From the OSD main menu, press 5 to select Camera Options.
2. Press 6 to set Vert Phase Edge to ON or OFF (default).
To set the vertical phase edge:
1. From the OSD main menu, press 5 to select Camera Options.
2. Press 6 to set Vert Phase Edge to ON.
3. Press 7 to select Vert Phase 0–359.9.
4. Type a value from 0 (default) through 359.9 and then press ENTER.
The value expresses, in degrees, the adjustment required overcome the
difference between connected AC supply phases.
Setting Image Stabilization
Electronic image stabilization (EIS) compensates for camera vibration,
minimizing image blur.
To enable/disable image stabilization:
1. From the OSD main menu, press 5 to select Camera Options.
2. Press 3 to select Video Setup.
3. Press 8 to set image stabilization to 5Hz, 10 Hz, or OFF (default).
Note If image stabilization is enabled, the digital zoom is restricted to 2×.

Table of Contents

Other manuals for Honeywell equIP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell equIP Series and is the answer not in the manual?

Honeywell equIP Series Specifications

General IconGeneral
BrandHoneywell
ModelequIP Series
CategorySecurity Camera
LanguageEnglish

Related product manuals