EQUIP
®
Series ACUIX™ IP PTZ Dome Installation and Configuration Guide
Document 800-04194V1 Rev A 69
07/11
Line lock can also help an analog VCR to remain in sync when switching
between properly adjusted, line-locked cameras. Line lock is generally of no
benefit with digital (LCD or flat screen) monitors and DVRs.
Note You need an AC power supply to use this feature.
To enable/disable vertical phase edge:
1. From the OSD main menu, press 5 to select Camera Options.
2. Press 6 to set Vert Phase Edge to ON or OFF (default).
To set the vertical phase edge:
1. From the OSD main menu, press 5 to select Camera Options.
2. Press 6 to set Vert Phase Edge to ON.
3. Press 7 to select Vert Phase 0–359.9.
4. Type a value from 0 (default) through 359.9 and then press ENTER.
The value expresses, in degrees, the adjustment required overcome the
difference between connected AC supply phases.
Setting Image Stabilization
Electronic image stabilization (EIS) compensates for camera vibration,
minimizing image blur.
To enable/disable image stabilization:
1. From the OSD main menu, press 5 to select Camera Options.
2. Press 3 to select Video Setup.
3. Press 8 to set image stabilization to 5Hz, 10 Hz, or OFF (default).
Note If image stabilization is enabled, the digital zoom is restricted to 2×.