Chapter 6
Removing and Replacing Components
Removing and Replacing the System Board
220
Step 9. Replace the top cover.
Step 10. Reconnect all power and external cables and turn on the server.
Step 11. If you have installed a new system board, you must write the serial number and model string data
to the new system board. To write the server information to the new system board, follow these
steps:
a. Locate the system serial number and note it for use in the following steps. The system serial
number is found in two places:
On the left of the front bezel, but to the right of the disk drives, locate the pull tab and
extend the tab from the server to display product information. A label containing the system
serial number is attached to the pull tab. (Figure 6-73 on page 222)
A label containing the system serial number is located on the right side of the chassis, as
you face the server.
b. Monitor server startup on a terminal. At the BCH prompt, enter the SER command to call up the
service menu. (See the Utilities chapter for additional information about BCH.)
c. At the service menu prompt, enter the INIT command to enter original product number and
system serial number.
d. When prompted to change, enter the product number that is on the pull tab and confirm by
entering Y when prompted.
e. When prompted, enter the system serial number.
f. When prompted, enter Y to confirm the change.
NOTE If your product is a base system that is one processor 800mhz CPU, skip steps g-j
and go to step k to reset the server.
g. Enter the upgrade command at the service menu prompt. You will be asked for the system
serial number.
h. Enter the same system serial number as you previously entered from the pull-out tag.
i. Enter the key from the key certificate that is on the back of the pull-out tag. The key certificate
number must be the number that applies to this system serial number or all the system
components will not be fontanel.
A current system value displays (rp3410 dc--) with the upgraded system value (the original
value). The following prompt displays:
Do you wish to continue with the change?
j. Enter Y to continue with the change.
k. Enter the RESET command to reset the server with the changes in effect.
NOTE If you performed an upgrade, the certificate shows a new key and model number to
be used
Step 12. Verify the system board replacement and operation by using the system utilities. (See the Utilities
chapter or the HP Integrity and HP 9000 iLO MP Operations Guide for additional information.)