CONTROLS
SECTION 2B. FAILURE ANALYSIS
2B-4
PROBLEM PROBABLE CAUSE REMEDY
21. Engine does not shut a. Faulty electrical circuit. a. See Section 10B.
down when operator
leaves seat (implement
switch ON).
22. Panel lights do not come a. 10 amp gauge/panel light circuit a. Reset/test (Section 10J).
on when test switch is breaker tripped.
pushed to the ON
b. Battery dead. b. Charge/replace (Section 10D).
position.
c. 50 amp tractor circuit breaker c. Test (Section 10J).
tripped.
d. Faulty electrical circuit. d. See Section 10B.