(See Figure 10I-4)
7. Set multimeter to 200 Ω (ohms) range.
8. Connect multimeter leads to coil as shown.
•
Coil Ω (ohms) reading should be approximately
10 Ω (ohms) if reading is correct. Valve car-
tridge may be faulty.
•
Coil Ω (ohm) reading not to specification, change
coil.
ELECTRICAL SYSTEM
SECTION 10I. SOLENOIDS
10I-4
Figure 10I-4. Solenoid Coil Test