EasyManuals Logo

Keithley 2001 User Manual

Keithley 2001
488 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #422 background imageLoading...
Page #422 background image
C
IEEE-488.2 Common Commands
C-1
Mnemonic Name Description
*CLS Clear status Clears all event registers, and Error Queue.
*ESE <NRf> Event Enable command Sets the contents of the Standard Event Enable Register.
*ESE? Event Enable query Request the programmed value of the Standard Event Enable Register.
*ESR? Event status register query Request the programmed value of the Standard Event Status Register and
clears it.
*IDN? Identification query Request the manufacturer, model number, serial number, and firmware
revision levels of the unit.
*OPC Operation complete command Sets the Operation Complete bit in the Standard Event Status Register
after all pending commands have been executed.
*OPC? Operation complete query Places an ASCII “1” into the output queue when all pending selected
device operations have been completed.
*OPT? Option identification query Returns an ID code that indicates which memory option is installed and
whether or not the optional scanner card is installed.
*RCL <NRf> Recall command Returns the Model 2001 to the setup configuration stored in the desig-
nated memory location.
*RST Reset command Returns the Model 2001 to the *RST default conditions.
*SAV <NRf> Save command Saves the current setup configuration to the designated memory location.
*SRE <NRf> Service request enable command Sets the contents of the Service Request Enable Register.
*SRE? Service request enable query The Model 2001 returns the value of the Service Request Enable
Register.
*STB? Read status byte query Returns the value of the Status Byte Register.
*TRG Trigger command This command issues a bus trigger which has the same effect as group
execute trigger (GET) command.
*TST? Self-test query When this query is sent, the Model 2001 will perform a checksum test on
ROM and return the results.
*WAI Wait-to-continue command Wait until all previous commands are executed.

Table of Contents

Other manuals for Keithley 2001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2001 and is the answer not in the manual?

Keithley 2001 Specifications

General IconGeneral
Model2001
CategoryMultimeter
ManufacturerKeithley
TypeDigital Multimeter
Digits of Resolution7.5
DC Voltage Range100 mV to 1000 V
AC Voltage Range100 mV to 750 V
Frequency Range3 Hz to 500 kHz
ConnectivityGPIB, RS-232
DisplayVFD
Resistance Accuracy0.008% + 2.0 mΩ
Frequency Accuracy±0.01%
DC Current Range10 μA to 3 A
AC Current Range10 μA to 3 A
Power Supply100 V to 240 V AC, 45 Hz to 66 Hz