3-6 Keysight B1505A Configuration and Connection Guide
N1265A Connection Guide
Input Connection
Table 3-2 To Connect between B1505A and N1265A, without HVMCU and UHVU
B1505A terminals Required cables N1265A terminals
Interlock
16493J Interlock cable, 3 m or 1.5 m, 1 ea.
Interlock
1
GNDU
16493L GNDU cable, 3 m or 1.5 m, 1 ea.
GNDU
2
HVSMU
Force 16493T HVSMU cable, 3 m or 1.5 m, 1 ea.
Selector Input
HVSMU
3
HPSMU
or
MPSMU
Force 16494A Triaxial cable, 3 m or 1.5 m, 1 ea., for the non-Kelvin
connection, connect it between the Force connectors.
For the Kelvin connection, prepare additional one more cable and
connect it between the Sense connectors.
Selector
Input
SMU
Force
Sense Sense
MCSMU
4
Force 16494A Triaxial cable, 3 m or 1.5 m, 1 ea.
UHC
Input
VControl
Force
Sense 16494A Triaxial cable, 3 m or 1.5 m, 1 ea. Sense
MCSMU
4
Force 16494A Triaxial cable, 3 m or 1.5 m, 1 ea.
UHC
Input
I Control
Force
Sense 16494A Triaxial cable, 3 m or 1.5 m, 1 ea. Sense
MCSMU
4
Force 16494A Triaxial cable, 3 m or 1.5 m, 1 ea.
Gate
Force
Sense 16494A Triaxial cable, 3 m or 1.5 m, 1 ea. Sense
MCSMU
or
HPSMU
or
MPSMU
Force To connect MCSMU, use two 16494A cables, 3 m or 1.5 m.
To connect HP/MPSMU, use N1261A-001 protection adapter and
four 16494A triaxial cables for Kelvin connection or two 16494A
cables for non-Kelvin connection. Recommended cable length is
1.5 m. See "To Connect Protection Adapter" on page 5-23 for
protection adapter.
SMU
1/2/3
See Table
3-1.
[1]/[3]
/[5]
Sense [2]/[4]
/[6]
HCSMU
or
DHCSMU
Force For HCSMU, 16493S HCSMU cable, 3 m or 1.5 m, 1 ea.,
N1254A-103 adapter for Force, and N1254A-517 adapter for
Sense
For DHCSMU, 16493S HCSMU cable, 3 m or 1.5 m, 1 ea.,
16493S-021 Dual HCSMU adapter, N1254A-103 adapter for
Force, and N1254A-517 adapter for Sense. See "To Connect
16493S-021" on page 5-22 for Dual HCSMU adapter.
SMU 3 [5]
Sense [6]
MFCMU Hpot N1300A-001 CMU cable 1 ea., N1260A high voltage bias-tee 1
ea., and N1254A-518 SHV(plug)-SHV(plug) cable 2 ea. See "To
Connect High Voltage Bias Tee" on page 5-25 for bias-tee.
It is not needed to connect the ground wire extended from the
CMU cable.
Bias Tee High
Hcur
Lcur Low
Lpot

Table of Contents

Other manuals for Keysight Technologies B1505A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies B1505A and is the answer not in the manual?

Keysight Technologies B1505A Specifications

General IconGeneral
BrandKeysight Technologies
ModelB1505A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals