3.
The electric pump may be assembled on application at a
maximum height of 500 mm from the position of the fuel
tank.
4.
Insert a shut-off valve to prevent dry operation due to the
emptying of the intake manifold;
5.
The supply pressure given from the electric pump must
not exceed the pressure of 0.2 bar to the input of
highpressure injection pump.
Tab 2.20
POS.
DESCRIPTION
1
Arrival pipe from the tank
2
Electric pump
3
Flow pipe to the fuel filter
4
Fuel filter
Fig 2.11