Appendix D: RINEX
265
Observations can be output in the order as defined in the header definition “# / TYPES OF OBSERV”.
TN / TE observations shall be set to ±9999.999999, if the measurement value is out of the measuring range of the tilt device.
File naming (applies to all auxiliary file versions)
Product file names are generated from the file creation date, time and type of product.
RINEX
PRODUCTS OF LENGTH OF 1 HOUR PLUS BY DEFAULT WILL BE NAMED: ssssdddh.yyo
ssss
4-character ID for the receiver/antenna
ddd
day of year
hh
character for the starting hour in the day
yy
two-digit year
o
type of file: a - auxiliary
RINEX
PRODUCTS WHOSE LENGTH IS LESS THAN 1 HOUR, E.G. 10 MINUTES, WILL BE NAMED:
ssssdddhmm.yyo
ssss
4-character ID for the receiver/antenna
ddd
day of year
hh
character for the starting hour in the day
yy
two-digit year
o
type of file: a - auxiliary
Overview of RINEX Auxiliary file version in RefWorx
Auxiliary File Version
Version of RINEX logging session
RefWx version
2.11
RINEX2
never
2.20
RINEX2
≥ 1.0
3.01
RINEX3
3.0x
3.02
RINEX3
≥ 3.1