To remove particles of dirt from the sys-
tem: Close flushing valve before the final
day of spraying.
Check whether the pump is switched off
via the PTO shaft.
Place a collection tray (1) under the filter
before cleaning.
Clean the suction filter.
Clean the pressure filter.
Return the flush valve to its original posi-
tion.
Remove the seal (1).
Loosen (3) union nut.
Remove the suction filter (2).
Clean the individual components of the
suction filter with water and a soft brush.
Install (2) suction filter.