Appendix
203
(*) 1.0 bar applies to IDKN only -01 ID/IDK: 20-90 l/ha (5-18 km/h)
Notes:
Spray pressure measured at the nozzle.
Lateral nozzle spacing 50 cm.
Spray height above the crop approx. 50 cm.
Spray pressure range:
ID nozzles:
2 3.5 bar
IDN nozzles:
2 4 bar
IDK nozzles:
1.5 2.5 bar
IDK nozzles (04/05/06):
>1.0 bar 2.5 bar
IDKN nozzles:
1.0 2.2 bar
FD nozzles:
1.5 - 4 bar
The data and applications listed in the nozzle tables must always be taken into
account.
For accurate dosing, volumetric metering is recommended on first
use and annually thereafter .
11.5.4 Dosage table, liquid fertiliser nozzle FD
Nozzle
(Colour)
Pressure
[bar]
l/min
UAN l/ha
H2O
UAN
km/h
6
8
10
14
18
03
(Dark blue)
1.5
0.85
0.75
150
113
90
64
50
2.0
0.98
0.86
172
129
103
74
57
3.0
1.20
1.06
212
159
127
91
71
4.0
1.39
1.22
244
183
146
105
81
04
(Red)
1.5
1.13
1.00
200
150
120
86
67
2.0
1.31
1.15
230
173
138
99
77
3.0
1.60
1.41
282
211
169
121
94
4.0
1.85
1.63
326
245
196
140
109

Table of Contents