103
It may be possible to return empty, clean canisters to the supplier of the spraying
agent.
Please ask your spraying agent supplier.
If a return is not possible:
Recycle the empty, clean spraying agent canisters.
6.7 Cleaning gun on the induction hopper
Observe the relevant standards and regulations for cleaning the
implement.
The cleaning gun must only be operated with fresh water.
Switch the selector switch to the fresh
water tank.
Switch on the pump.
Operate the pump at approximately 400
rpm.
For a maximum cleaning effect of the
cleaning gun, the edge wetting, proflow
nozzle, agitator nozzle and the canister
flushing nozzle should be switched off.
Close the edge wetting lever by swit-
ching it down to OFF.
Close the agitator nozzle lever by swit-
ching it down to OFF.
Close the canister flushing lever by swit-
ching it down to OFF.