Technical data
187
10.11 Pumps
Device
Working pump
Agitator pump
2500
P260
3500
P260
4500
P200
P200
Data per pump
Type
P 260
P 200/P200
PTO shaft
DIN 9611 / ISO 500
Design
Piston diaphragm pump
Number of pistons
2 x 4
Connection
Hose
Internal Ø suction side,
minimum [mm]
50
50
Internal Ø pressure side,
minimum [mm]
31.00
31.50
Operating pressure [bar]
15
Nominal pressure [bar]
20
Permissible negative pressure [bar]
0.3
Maximum suction depth [m]
3
Pressure in accumulator [bar]
Optimum:
Pressure in accumulator = spray pres-
sure
Around:
4 bar at a spray pressure of
1 10 bar
6 bar at a spray pressure of
5 15 bar

Table of Contents