Technical data
189
Filling connection, capacity
Maximum filling capacity [l/min]:
500
Maximum filling pressure [bar]:
5
Suction connection, capacity
Maximum vacuum pressure [bar]:
- 0.3
Maximum suction height [m]
3
Minimum suction hose diameter [mm]:
2
Maximum suction hose length with hose at ground level [m]:
20
Filler hose
Connection to implement:
2" Kamlock connector
Length of hose
5 m or 8 m
Hose end:
Filter sieve 4" or 2" Kamlok connector
10.13 Oil hydraulic system
10.13.1 Device system
Pressure
[bar]
Required pressure in the tractor hydraulics for the hydraulic
ram on the device side [bar]:
160
Maximum permissible:
200
The hydraulic system is filled with hydraulic oil HLP 46 in accordance with
ISO VG 46; DIN 51 524 T.2.
10.13.2 Volumetric flow and pressure
Function
[l/min]
Folding the sprayer boom (P2/T2)
10
Height adjustment of the sprayer boom up to B30 (P1)
18
Electrohydraulic operation up to B30 (P6T6) without steering
24