EasyManua.ls Logo

LEMKEN Primus 10 - Nozzle Sizes 06 - 10; Correction Factors for Spraying Liquids with Different Densities

LEMKEN Primus 10
218 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
196
Nozzle spacing:
50 cm
l/ha
Flow
100
125
150
175
200
225
250
300
350
400
500
l/min
01
015
02
025
03
04
05
31.2
25.0
20.8
17.8
15.6
13.9
12.5
10.4
8.9
7.8
6.2
2.60
7.9
5.1
32.4
25.9
21.6
18.5
16.2
14.4
13.0
10.8
9.3
8.1
6.5
2.70
8.5
5.5
33.6
26.9
22.4
19.2
16.8
14.9
13.4
11.2
9.6
8.4
6.7
2.80
9.2
5.9
34.8
27.8
23.2
19.9
17.4
15.5
13.9
11.6
9.9
8.7
7.0
2.90
9.9
6.3
36.0
28.8
24.0
20.6
18.0
16.0
14.4
12.0
10.3
9.0
7.2
3.00
6.7
37.2
29.8
24.8
21.3
18.6
16.5
14.9
12.4
10.6
9.3
7.4
3.10
7.2
38.4
30.7
25.6
21.9
19.2
17.1
15.4
12.8
11.0
9.6
7.7
3.20
7.7
39.6
31.7
26.4
22.6
19.8
17.6
15.8
13.2
11.3
9.9
7.9
3.30
8.2
40.8
32.6
27.2
23.3
20.4
18.1
16.3
13.6
11.7
10.2
8.2
3.40
8.7
42.0
33.6
28.0
24.0
21.0
18.7
16.8
14.0
12.0
10.5
8.4
3.50
9.2
43.2
34.6
28.8
24.7
21.6
19.2
17.3
14.4
12.3
10.8
8.6
3.60
9.7
44.4
35.5
29.6
25.4
22.2
19.7
17.8
14.8
12.7
11.1
8.9
3.70
10.3
- - - = Example: 200 l/ha at 7.2 km/h requires 1.20 l/min per nozzle, i.e. 6.7 bar in size -02,
4.3 bar in size -025, 3.0 bar in size -03, etc.
11.3.2 Nozzle sizes 06 - 10
Nozzle spacing:
50 cm
l/ha
Flow
100
125
150
175
200
225
250
300
350
400
500
l/min
06
08
10
45.6
36.5
30.4
26.1
22.8
20.3
18.2
15.2
13.0
11.4
9.1
3.80
7.5
4.2
2.7
46.8
37.4
31.2
26.7
23.4
20.8
18.7
15.6
13.4
11.7
9.4
3.90
7.9
4.5
2.9
48.0
38.4
32.0
27.4
24.0
21.3
19.2
16.0
13.7
12.0
9.6
4.00
8.3
4.7
3.0
49.2
39.4
32.8
28.1
24.6
21.9
19.7
16.4
14.1
12.3
9.8
4.10
8.8
4.9
3.2
50.4
40.3
33.6
28.8
25.2
22.4
20.2
16.8
14.4
12.6
10.1
4.20
9.2
5.2
3.3
51.6
41.3
34.4
29.5
25.8
22.9
20.6
17.2
14.7
12.9
10.3
4.30
9.6
5.4
3.5
52.8
42.2
35.2
30.2
26.4
23.5
21.1
17.6
15.1
13.2
10.6
4.40
10.1
5.7
3.6
54.0
43.2
36.0
30.9
27.0
24.0
21.6
18.0
15.4
13.5
10.8
4.50
5.9
3.8
55.2
44.2
36.8
31.5
27.6
24.5
22.1
18.4
15.8
13.8
11.0
4.60
6.2
4.0
56.4
45.1
37.6
32.2
28.2
25.1
22.6
18.8
16.1
14.1
11.3
4.70
6.5
4.1
57.6
46.1
38.4
32.9
28.8
25.6
23.0
19.2
16.5
14.4
11.5
4.80
6.8
4.3
58.8
47.0
39.2
33.6
29.4
26.1
23.5
19.6
16.8
14.7
11.8
4.90
7.0
4.5
60.0
48.0
40.0
34.3
30.0
26.7
24.0
20.0
17.1
15.0
12.0
5.00
7.3
4.7
11.4 Correction factors for spraying liquids with different densities
Density of the
spraying liq-
uid
0.84
0.96
1.00
1.11
1.24
1.28
1.32
1.38
1.44
1.50
Water
Urea
ASL
AHL
(28)
AHL +
S
AHL
(30)
NP
solution
Correction fac-
tor
1.09
1.02
1.00
0.95
0.90
0.88
0.87
0.85
0.83
0.81

Table of Contents

Related product manuals