Loosen the union nut (2) of the pressure
filter.
Remove the pressure filter.
Clean the individual components with
water and a soft brush.
Install pressure filter.
When mounting, ensure the seal (3) is
correctly inserted and not crushed.
Open flushing valve (F) if necessary.