81
Adjusting the control
Select the manual mode to control the
distribution rate in the control system.
The work mask view changes.
Determine the intended spray pressure
of the built-in nozzles in the nozzle table.
Volumetric metering
Go to a nozzle and collect the water for
exactly 60 seconds with the prepared
measuring cup.
Write down the amount of water applied.
Repeat the last two steps on at least 3
nozzles with different part-width sec-
tions.
Compare the amount of water applied by
the individual nozzles.
If the output quantities of the measured
nozzles are equal and the l/min value cor-
responds to the value of the nozzle table:
Calibrate the flowmeter.