Diagnostic aids 3-29
5060-4xx
• If you select Media 2 from the menu the following is displayed and the sensors polled:
Once the sensors are polled the following is displayed and the sensors are ready to test.
Once the screen is displayed you can manually actuate each of the sensors. When the sensor is
closed, CL is displayed, when the sensor is open OP is displayed.
• If you select Media 3 from the menu the following is displayed and the sensors polled:
Once the sensors are polled the following is displayed and the sensors are ready to test:
Once the screen is displayed you can manually actuate the sensor. When the sensor is closed, CL is
displayed, when the sensor is open OP is displayed.
• If you select Media Level from the menu the following is displayed and the sensors polled:
Once the sensors are polled the following is displayed and the sensors are ready to test:
Once the screen is displayed you can manually actuate the sensor. When the sensor is closed, CL is
displayed, when the sensor is open OP is displayed.
2. To exit the sensor test, press Return or Stop.
Hole Punch Test
Use this test to verify that media can be fed to the Finisher output bin and hole punched. Letter or A4 size media
must be used in the source tray for this test. Eight sheets of blank paper are fed and holes punched with a three
hole or four hole pattern.
To run the test in Diagnostics Mode:
1. Select Hole Punch Tests from FINISHER TESTS in the Diagnostics mode.
2. Select 3 Punch Test or 4 Punch Test.
3. Press Return after the test is complete to exit the test.
Media Path 2
Testing............
Media Path 2
S3=OP S4=OP
S3 =Inverter Jam Sensor
S4 =Drop Timing Sensor
Media Path 3
Testing..........
Media Path 3
S5=OP S6=OP
S5 =Exit Timing Sensor
Media Level
Testing...........
Media Level
S1=OP S2=OP
S1 =Tray limit switches
S2 =Paper surface sensor