2-14 Service Manual
5060-4xx
Programming errors - P101 through P116
These error codes may be displayed whenever a new code upgrade has been attempted. It is possible that the
wrong type of code, network versus non-network, or a corrupted file was probably sent to the printer. Verify that
the correct type of code is being flashed to the printer.
The following displays whenever a programming error occurs while programming the RIP code.
Programming
Error Pxxx
Error code Description
P101
P104
Bad file type - The proper signature was not found in the file.
P102 Device size error - The flash file was too large to fit on the flash device.
P103 Copyright too large - The copyright message was too large to fit into one block.
P104 Not used
P105 Invalid package - A network file was used to program a non-network printer, or a
non-network file was used to program a network printer.
P106 Not used (invalid chip select)
P107 Not used (invalid Block Table (IBT) is not valid)
P108 Invalid socket - The socket ID requested for programming is not valid.
P109 Package size error - An update file was used to program the printer, but the
package did not fit within the space allocated in the Master Boot Record.
P110 Too many bad blocks - The Invalid Block Table is too large to fit in the allocated
space.
P111 Boot Loader too large - The Boot Loader (zloader) is too large to fit into block 0.
P112 Invalid DLE - An upddle.fls file was used to update the DLE code on printer with a
firmware card installed, but the DLE was not found on the firmware card.
P113 Not used (no partition specified)
P114 Bad secure header - The secure header for the DLE was invalid.
P115 Invalid package - A non-DLE “full” file was sent to a flash that already had a DLE
partition. (You must use erasele.fls to wipe out the DLE partition first).
P116 User Flash partition in use - An attempt was made to program code over a user
flash part.