4-80 Service Manual
5060-4xx
Waste container latch
Go to “Waste container latch” on page 7-26 for part number.
1. Remove the paper size sensing assembly. See “Paper size sensing assembly” on page 4-55.
2. Use a flatblade screwdriver to release the waste container latch from the paper size sensing assembly.
Web oiler fuser kit installation
1. Enter Diagnostic mode. See “Entering Diagnostics mode” on page 3-13.
2. Select PRINTER SETUP.
3. Select Configuration ID.
4. Increase the last two digits each by four.
The left digit blinks, indicating it is the first digit to be changed. Press Select to accept the current value and
skip to the next digit. Change the two digits on the right to increase each of their values by four. For
example, in this case, change 123456 to 12349A. To change the value of a digit, press Menu until the
desired value is displayed and press Select. When the last (rightmost digit) is changed and Select is
pressed, the new value is set. The printer automatically begins POR.
5. Turn the printer off.
6. Open the fuser access cover.
Configuration ID
=123456*