Repair information 4-27
5060-4xx
17. Reattach the spring clip to the pick arm. Make sure the pick arm rotates freely from top to bottom in the
machine.
18. Once the pick assembly is in place, put the four screws for the pick assembly back into place. Placing the
front side screw in first makes it easier to put in the rest of the screws. When starting the front screw, push
the pick assembly towards the front of the printer.
19. Reconnect the connectors.
20. Reattach the paper lever sensor (three screws).
21. Position the mylar piece using two screws or one cable tie. When you place the mylar piece, make sure you
place it back under the metal bar (M) under the inner deflector. if a cable tie is used to secure the mylar
piece, make sure that the blue cable running under the mylar piece is retained by the cable tie.
M