5 Select Quick Test Page. The test page should only be printed on letter or A4 paper from Tray 1. The Quick Test Page
consists of alignment diamonds and horizontal lines that can be used for mechanical registration adjustment. The
following image shows an example of the Quick Test Page:
6 Review the page to determine which type of skew is present.
Note: Make sure that the side guide and rear guide are properly set in the paper tray before printing test pages
or making adjustments. Out-of-position guides can contribute to print skew.
For top margin skew (or after the media aligner rollers are replaced), go to “Media aligner roller adjustment” on
page 376.
For skew on both the top and bottom margins, or mainly the bottom margin, it is recommended that the “Media aligner
roller adjustment” on page 376 be made to set the leading edge parallel to the trailing edge, and then make the
“Polygon printhead mechanical registration adjustment” on page 377 to bring both margins into alignment. A final
media aligner roller adjustment might be required at the end of the process, after the bottom skew is adjusted out.