EasyManua.ls Logo

Lexmark MS711 - Sensor (Fuser Exit) Miscellaneous Jam Service Check; Sensor (Narrow Media) Static Jam Service Check

Lexmark MS711
949 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sensor (narrow media) static jam service check
Action Yes No
Step 1
Check the fuser for jammed media.
Is the fuser path free from jammed media?
Go to step 2. Remove any jammed
media.
Step 2
Check the sensor (fuser exit) for proper operation.
a Enter the diagnostic mode.
b Select Base sensor test.
c Observe the line item fuser exit.
Does the display on the control panel change every time the sensing area
of the above sensor is interrupted or blocked?
Go to step 4.Go to step 3.
Step 3
Check the above sensor for proper connection.
Is the above sensor connected properly?
Replace the fuser. See
“Fuser removal” on
page 459.
Go to step 4.
Reseat the connection.
Go to step 4.
Step 4
Perform a print test.
Does the problem remain?
Contact the next
highest level of
technical support.
Problem solved.
Sensor (fuser exit) miscellaneous jam service check
Action Yes No
Step 1
Check the sensor (fuser exit) for proper operation.
a Enter the diagnostic mode.
b Select Base sensor test.
c Observe the line item fuser exit.
Does the display on the control panel change every time the sensing area
of the above sensor is interrupted or blocked?
Go to step 3.Go to step 2.
Step 2
Check the above sensor for proper connection.
Is the above sensor connected properly?
Replace the fuser. See
“Fuser removal” on
page 459.
Reseat the connection.
Step 3
Perform a print test.
Does the problem remain?
Contact the next level
of technical support.
Problem solved.