5 Disconnect the cable, remove the mylar cover (C). Release the latches to remove the sensor from the bracket. Pull
the sensor off the bracket, and remove.
C
HCOE belt tensioner removal
1 Remove the HCOE right cover. See “HCOE right cover removal” on page 588.
2 Remove the HCOE latch.See “HCOE option latch removal” on page 594.
3 Remove the HCOE tray pinion. See “HCOE tray pinion removal” on page 598.
4 Remove the HCOE drive belt. See “HCOE drive belt removal” on page 602.
5 Remove the screw (A) from the tensioner.
4063
Repair information