Stapler diverter plunger assembly removal
1 Remove the finisher left cover. See “Staple, hole punch left cover removal” on page 739.
2 Remove the three screws (A) from the main motor bracket.
A
Note: Removing the main motor bracket will not be required. Just move it out of the way to make it easier to
release the diverter motor bracket.
3 Remove the two screws (B) from the diverter motor bracket.
B
Note: Removing the diverter motor bracket will not be required. Just move it out of the way to access the parts
underneath it.
4063
Repair information
754