4 Remove the left cover. See “Left cover removal” on page 489.
5 Remove the PCBA housing. See “PCBA housing removal” on page 500.
6 Remove the media tray. See “Media tray removal” on page 479.
7 Remove the pick roller assembly. See “Pick roller assembly removal” on page 482.
8 Remove the media feeder. See “Media feeder removal” on page 498.
9 Disconnect the cable (A) from the sensor (tray 1 media out).
10 Release the hooks (B) securing the sensor (tray 1 media out) to the media feeder.