9 Remove the three screws (C) securing the bottom part of the motor assembly.
C
10 Release the cables off their guides.
Note: Pay attention to the original routing of the cables.
11 Pull the motor assembly away from the machine.
12 Remove the screw (D) securing the sensor bracket. Pull the bracket and separate it from the motor assembly.
D
Installation note: Make sure the paddles (E) align and fit properly.