Gocator Line Profile Sensors: User Manual
Gocator Web Interface 188
Measurement Illustration
Flush
Measures the flushness between two surfaces. The surface
edges can be curved or sharp.
Parameter Description
Max Gap Width The maximum width of the gap. Allows the tool to filter gaps greater than the expected
width. This can be used to single out the correct gap when there are multiple gaps in the
field of view.
Reference Side Defines the side used to calculate the measurement axis (see below).
Measurement Axis
Gap measurement only
Defines the direction that the gap is calculated, in relation to the reference side (see
above).
Surface: In the direction of the fitted surface line of the reference surface.
Edge: In the direction perpendicular to the edge of the reference surface.
Distance: The Cartesian distance between the two feature locations.
Absolute
Flush measurement only
When enabled, returns an absolute value rather than a signed value.
Decision See Decisions on page 159.
Region See Regions on page 158.
Output See Filters on page 161.
Parameters
Parameter Description
Max Void Width The maximum allowed width of missing data caused by occlusion or data dropout.
Min Depth Defines the minimum depth before an opening could be considered to have a potential
edge. The depth is the perpendicular distance from the fitted surface line.
Surface Width The width of the surface area in which laser data is used to form the fitted surface line.
This value should be as large as the surface allows.
Left/Right SideParameters