Gocator Line Profile Sensors: User Manual
Gocator Device Files • 314
Element Type Description
StreamOptions Collection
A collection of StreamOption on page 299 elements.
Stream\Step
32s The stream source step. Possible values are:
1 – Video
2 – Range
3 – Surface
4 – Section
Stream\Id 32u The stream source ID.
RefSide 32s Setting for reference side to use.
MaxGapWidth 64f Setting for maximum gap width (mm).
LeftEdge
ProfilePanelEdge
Element for left ede configuration.
RightEdge
ProfilePanelEdge
Element for right edge configuration.
Measurements\Gap
Gap measurement
Gap measurement.
Measurements\Flush
Flush measurement
Flush measurement.
Element Type Description
EdgeType 32s
Edge type:
0 – Tangent
1 – Corner
MinDepth 64f Minimum depth.
MaxVoidWidth 64f Maximum void width.
SurfaceWidth 64f Surface width.
SurfaceOffset 64f Surface offset.
NominalRadius 64f Nominal radius.
EdgeAngle 64f Edge angle.
RegionEnabled Bool Whether or not to use the region. If the region is disabled,
all available data is used.
Region
ProfileRegion2d
Edge region.
ProfilePanelEdge
Element Type Description
@id 32s Measurement ID. Optional (measurement disabled if not
set).
Name String Measurement name.
Enabled Boolean
Measurement enable state:
0 – Disable
1 – Enable
HoldEnabled Boolean
Output hold enable state:
Gap Measurement