Gocator Line Profile Sensors: User Manual
Protocols • 400
Indicator ID Instance Value
Ethernet Drops 21005 - Number of dropped Ethernet packets.
Digital Output Pass 21006 Output Index Number of pass digital output pulse.
Digital Output Fail 21007 Output Index Number of fail digital output pulse.
Trigger Drops** 21010 Number of dropped triggers. The sum of various
triggering-related drop indicators.
Output Drops** 21011 Number of dropped output data. The sum of all
output drops (analog, digital, serial, host server,
and ASCII server).
Host Server Drops** 21012 The number of bytes dropped by the host data
server. Not currently emitted.
ASCII Server Drops** 21013 The number of bytes dropped by the ASCII
Ethernet data server. Not currently emitted.
Range Valid Count** 21100 - Number of valid ranges.
Range Invalid Count** 21101 - Number of invalid ranges.
Anchor Invalid Count** 21200 - Number of frames with anchoring invalid.
Z-Index Drop Count 22000 - The number of dropped surfaces due to a lack of z-
encoder pulse during rotational part detection.
Value 30000 Measurement ID Measurement Value.
Pass 30001 Measurement ID Number of pass decision.
Fail 30002 Measurement ID Number of fail decision.
Max 30003 Measurement ID Maximum measurement value.
Min 30004 Measurement ID Minimum measurement value.
Average 30005 Measurement ID Average measurement value.
Std. Dev. 30006 Measurement ID Measurement value standard deviation.
Invalid Count 30007 Measurement ID Number of invalid values.
Overflow 30008 Measurement ID
Number of times this measurement has overflown
on any output. Multiple simultaneous overflows
result in only a single increment to this counter.
Overflow conditions include:
-Value exceeds bit representation available for
given protocol
-Analog output (mA) falls outside of acceptable
range (0-20 mA)
When a measurement value overflow occurs, the
value is set to the null value appropriate for the
given protocol's measurement value output type.
The Overflow health indicator increments.
*When the sensor is accelerated, the indicator's value is reported from the accelerating PC.